Every unit tells you what it is. Here is how to read it.

Each air conditioner, heat pump and air handler carries a stamped data plate. It gives the size, the power it needs and the refrigerant inside. Pick a field on the sample plate below to see what it means, then use the guides to size and choose equipment for hot, humid weather.

Heat pump outdoor unitSample plate

Suitable for outdoor use. Values are an example, not a real model.

  1. Model number: the size is hidden in it

    Look for a two or three digit number divisible by 6. It is the nominal capacity in thousands of Btu per hour: 024 is 2 tons, 036 is 3 tons, 048 is 4 tons, 060 is 5 tons.

  2. Serial number: usually the build date

    Most makers code the year and week or month of manufacture into the serial. The format differs by brand, so look up the maker's key before trusting a guess.

  3. Volts, phase, hertz: the supply it needs

    Most home outdoor units are 208/230 volt, single phase, 60 hertz. A 3 in the phase box means commercial three-phase power, which houses rarely have.

  4. RLA and LRA: compressor current

    Rated load amps is what the compressor draws at its rating point. Locked rotor amps is the brief surge at start-up. A running reading well above RLA is a warning sign.

  5. Fan motor FLA and horsepower

    Full load amps and size of the outdoor fan motor. A replacement motor has to match these along with speed and rotation.

  6. Minimum circuit ampacity sizes the wire

    The branch circuit conductors must be rated to carry at least this current. It is already worked out for you: 125% of the compressor RLA plus the other loads.

  7. Maximum fuse or breaker

    The largest overcurrent device allowed on the circuit. It is higher than the wire rating on purpose, so the start-up surge does not trip it. Do not go above it.

  8. Refrigerant and factory charge

    The only refrigerant this unit may use, and the weight shipped in it. Refrigerants do not mix or swap. New equipment uses R-454B or R-32; older plates say R-410A or R-22.

  9. Design pressures

    The highest pressures each side of the system was built and tested to hold. They are safety limits for whoever services the unit, not normal running pressures.

Not on the plate: efficiency

Cooling, seasonal
15.2 SEER2
Cooling, at 95°F
12.0 EER2
Heating, seasonal
7.8 HSPF2

Sample ratings for one matched outdoor and indoor pair.

Where the efficiency numbers live

The data plate tells you what a unit needs. It usually does not tell you how efficient it is. Those ratings sit on the yellow EnergyGuide label and in the AHRI certificate for the system.

That is because efficiency belongs to a matched combination, not a single box. The same outdoor unit earns a different SEER2 with a different indoor coil or blower. When you compare quotes, ask for the AHRI reference number of the exact pairing and check that the model numbers on it match what gets installed.

Three ratings cover nearly everything. SEER2 is cooling efficiency averaged over a season. EER2 is cooling efficiency at a steady 95°F outdoors, which matters where afternoons stay hot for months. HSPF2 is heating efficiency for heat pumps. Higher is better for all three. The equipment overview lists the federal minimums and explains how far above them it makes sense to go.

Equipment guides

One page per kind of equipment: what it is, how it works, how to size it and what to check before buying or replacing it.

  • Split systems

    The common central setup: a condensing unit outside, a coil and blower inside, copper lines between.

    1.5 to 5 tons
  • Central air conditioners

    Cooling-only systems: when one makes sense, which tier to buy and how well it dries the air.

    14.3 SEER2 and up
  • Heat pumps

    An air conditioner that also runs in reverse. In mild winters it can be the only heat a house needs.

    SEER2 + HSPF2
  • Mini splits

    Ductless systems for one room or several, with inverter compressors that run long and slow.

    9,000 to 36,000 Btu/h
  • Package units

    Everything in one outdoor cabinet, ducted through the wall or roof.

    2 to 5 tons
  • Condenser units

    The outdoor half: compressor, coil and fan, plus salt air protection and storm anchoring.

    208/230 V
  • Air handlers

    The indoor half: blower, evaporator coil, heat strips and the drain that carries the humidity away.

    350 to 400 CFM per ton
  • Water heaters

    Tank, tankless and heat pump water heaters compared, with the sizing numbers for each.

    UEF, FHR, GPM

Not sure which type fits the house? Start with how to pick between system types.

What changes in a hot, humid climate

Most buying advice is written for places with dry summers or hard winters. Along the Gulf and in Florida the priorities are different, and every guide here is written with these four in mind.

  • Moisture is half the job

    An air conditioner cools air and wrings water out of it. A unit that is too big cools the house fast, shuts off and leaves the air clammy. Sizing a split system covers why slightly small beats slightly large.

  • Salt air eats outdoor coils

    Near the coast, salt spray corrodes fins and tubing years ahead of schedule. Coil material, coatings and a garden hose all matter. See condenser units.

  • A heat pump can be the whole heating system

    Where winter lows rarely get near freezing, a heat pump covers nearly every heating hour without help, and the backup heat strips seldom run.

  • Outdoor units have to stay put

    Hurricane-prone areas require outdoor equipment to be anchored against wind, and raised where flooding is expected. The condenser guide shows what a proper tie-down looks like.